Doc Number: X3T9.2/92-22 Date: January 17, 1992 Author: G. Penokie/C. Mosley Desc: SPI Connector Contact Working Group Minutes 1/15/92 SCSI-3 Connector Contact Meeting Attendees Name Organization ---------------------- ------------------------- Mr. Robert C. Herron 3M Company Mr. Jim Havener 3M Company Mr. Charles Brill AMP, Inc. Mr. Bob Whiteman AMP, Inc. Mr. Ken Schreder AMP, Inc. Mr. Bill Garver AMP, Inc. Mr. Edward Hrvatin Burndy Corp. Mr. Geoffrey Hyman Cables To Go Mr. George Zisk CW Industries Dr. William Ham Digital Equipment Corp. Mr. Mark Sausert ELCO Corp. Mr. Tom Kulesza Honda Connector Mr. George Penokie IBM Corp. Mr. Claude Mosley IBM Corp. Mr. Larry Grasso IBM Corp. Mr. Tom Forrer IBM Corp. Mr. William D'Andrea J.S.T. Corporation Mr. Bob Masterson Methode Electronics, Inc. Mr. Jim McGrath Molex Inc. Mr. Max Bassler Molex Inc. Mr. Dave Bowen Molex Inc. Mr. Ram Battu Seagate chnology, Inc. Mr. Vit Novak Sun Microsystems, Inc. Mr. Dean Wallace Texas Instruments Mr. Harvey Waltersdorf Thomas & Betts 26 People Present Claude Mosley presented his SCSI-3 Connector proposal (see X3T9.2/92-16). There was a great deal of interest in Claudes' presentation. Many issues where discussed. The major points where as follows: Questions were asked as to what criteria Claude used to determine a connector failure. Claude indicated one criteria was that if the resistance increased by 100% or more after environmental testing the connector failed. This was acceptable, but questions about what test does the connector get exposed to was not settled. All players were asked to consider whether or not the EIA and IEC documents would be acceptable to define the these tests. In the discussions about surface finish Claude indicated that, although he calls out a surface finish of N5 or better, he realizes that a curved surface finish is difficult to measure. He would rather measure the porosity and verify that the number of mating cycles does not cause wear thru of the noble plated surface. There was a long discussion on how many connect/unconnects should be allowed in a SCSI connector system. It was finally agreed that 200 cycles with no wear thru of the noble plating was a reasonable number. The next topic was pin radius. Claudes' picture which shows a pin digging into a contact was enough to convince the non-connector people in the room that a radius was needed. After some talk about how to specify the radius it was agreed to call out the same thickness as todays pin (0.0156") with a radius of 0.045 +/- 0.005 ". The issue of which connectors should the radius be incorporated on was addressed. The general feeling was that it should at least apply to all the square pin style connectors which are in the standard today. The last major issue was wipe length. Claude showed that the numbers in the SCSI standard (A14 and A18 in figure 9) were way too conservative and should be changed. This caused quite a stir among the connector people but in the end it was agreed that the values would only be changed to values which did not cause any changes to existing connectors. The connector vendors where given the task of determining what the values of their pins are and getting that information to Claude before or at the next plenary meeting in February. George Penokie and Claude Mosley agreed to write a proposal which would incorporate the above agreements. This proposal will be distributed at the February SCSI meeting. Another SWIG on connector will then be held at the March SCSI meeting to discuss and finalize the proposal. The final proposal will then be presented to the plenary for a vote at the April SCSI meeting.