Document X3T9.2/92-046 R1 Mar. 20, 1992 TO: X3T9.2 Committee (SCSI) FROM: G. A. Houlder (Seagate) SUBJECT: Request for New Additional Sense Codes We recently came across some errors that could not be reported very well because none of the existing error codes were close enough to the problem we were trying to report. Therefore I am requesting that these error codes be assigned. ASC ASCQ DTLPWRSOMC DESCRIPTION --- ---- ---------- ---------------------------------------- 65h 00h DTLPWRSOMC Voltage Fault 09h 04h DT WR O Head Select Fault The above ASC and ASCQ field recommendations were made during consultations with George Penokie and Larry Lamers to assure there were no conflicts with other codes that have recently been accepted for SCSI-3 but aren't shown in the SCSI-2 document.