Use the following letters to position in the list
A B C D
E F G H
I J K
L M N
O P Q
R S T
U V W
X Y Z
D - Direct Access Block Device (SBC-4) Device Column key
.Z - Host managed zoned block device (ZBC) ---------------------
. T - Sequential Access Device (SSC-5) M = Mandatory
. P - Processor Device (SPC-2) O = Optional
. .R - C/DVD Device (MMC-6) V = Vendor specific
. . O - Optical Memory Block Device (SBC) Z = Obsolete -- with
. . M - Media Changer Device (SMC-3) [std] identifying
. . .A - Storage Array Device (SCC-2) last standard
. . . E - SCSI Enclosure Services device (SES-3)
. . . B - Simplified Direct-Access (Reduced Block) device (RBC)
. . . .K - Optical Card Reader/Writer device (OCRW)
. . . . V - Automation/Device Interface device (ADC-4)
. . . . F - Object-based Storage Device (OSD-2)
. . . . .
OP DZTPROMAEBKVF Description
82 O ALLOW OVERWRITE
85 OO O ATA PASS-THROUGH(16)
86 Z ZZ ZZZZZZZ ACCESS CONTROL IN
87 Z ZZ ZZZZZZZ ACCESS CONTROL OUT
A1 OO O ATA PASS-THROUGH(12)
top - bottom
D - Direct Access Block Device (SBC-4) Device Column key
.Z - Host managed zoned block device (ZBC) ---------------------
. T - Sequential Access Device (SSC-5) M = Mandatory
. P - Processor Device (SPC-2) O = Optional
. .R - C/DVD Device (MMC-6) V = Vendor specific
. . O - Optical Memory Block Device (SBC) Z = Obsolete -- with
. . M - Media Changer Device (SMC-3) [std] identifying
. . .A - Storage Array Device (SCC-2) last standard
. . . E - SCSI Enclosure Services device (SES-3)
. . . B - Simplified Direct-Access (Reduced Block) device (RBC)
. . . .K - Optical Card Reader/Writer device (OCRW)
. . . . V - Automation/Device Interface device (ADC-4)
. . . . F - Object-based Storage Device (OSD-2)
. . . . .
OP DZTPROMAEBKVF Description
A1 O BLANK
top - bottom
D - Direct Access Block Device (SBC-4) Device Column key
.Z - Host managed zoned block device (ZBC) ---------------------
. T - Sequential Access Device (SSC-5) M = Mandatory
. P - Processor Device (SPC-2) O = Optional
. .R - C/DVD Device (MMC-6) V = Vendor specific
. . O - Optical Memory Block Device (SBC) Z = Obsolete -- with
. . M - Media Changer Device (SMC-3) [std] identifying
. . .A - Storage Array Device (SCC-2) last standard
. . . E - SCSI Enclosure Services device (SES-3)
. . . B - Simplified Direct-Access (Reduced Block) device (RBC)
. . . .K - Optical Card Reader/Writer device (OCRW)
. . . . V - Automation/Device Interface device (ADC-4)
. . . . F - Object-based Storage Device (OSD-2)
. . . . .
OP DZTPROMAEBKVF Description
18 Z ZZZO Z COPY
39 Z ZZZO Z COMPARE
3A Z ZZZO Z COPY AND VERIFY
40 Z ZZZOZ CHANGE DEFINITION
5B O CLOSE TRACK/SESSION
89 O COMPARE AND WRITE
top - bottom
D - Direct Access Block Device (SBC-4) Device Column key
.Z - Host managed zoned block device (ZBC) ---------------------
. T - Sequential Access Device (SSC-5) M = Mandatory
. P - Processor Device (SPC-2) O = Optional
. .R - C/DVD Device (MMC-6) V = Vendor specific
. . O - Optical Memory Block Device (SBC) Z = Obsolete -- with
. . M - Media Changer Device (SMC-3) [std] identifying
. . .A - Storage Array Device (SCC-2) last standard
. . . E - SCSI Enclosure Services device (SES-3)
. . . B - Simplified Direct-Access (Reduced Block) device (RBC)
. . . .K - Optical Card Reader/Writer device (OCRW)
. . . . V - Automation/Device Interface device (ADC-4)
. . . . F - Object-based Storage Device (OSD-2)
. . . . .
OP DZTPROMAEBKVF Description
19 V MVV ERASE(6)
2C V OO ERASE(10)
93 M ERASE(16)
A6 O EXCHANGE MEDIUM
AC O ERASE(12)
top - bottom
D - Direct Access Block Device (SBC-4) Device Column key
.Z - Host managed zoned block device (ZBC) ---------------------
. T - Sequential Access Device (SSC-5) M = Mandatory
. P - Processor Device (SPC-2) O = Optional
. .R - C/DVD Device (MMC-6) V = Vendor specific
. . O - Optical Memory Block Device (SBC) Z = Obsolete -- with
. . M - Media Changer Device (SMC-3) [std] identifying
. . .A - Storage Array Device (SCC-2) last standard
. . . E - SCSI Enclosure Services device (SES-3)
. . . B - Simplified Direct-Access (Reduced Block) device (RBC)
. . . .K - Optical Card Reader/Writer device (OCRW)
. . . . V - Automation/Device Interface device (ADC-4)
. . . . F - Object-based Storage Device (OSD-2)
. . . . .
OP DZTPROMAEBKVF Description
04 MO OO FORMAT UNIT
04 O FORMAT MEDIUM
04 FORMAT
top - bottom
D - Direct Access Block Device (SBC-4) Device Column key
.Z - Host managed zoned block device (ZBC) ---------------------
. T - Sequential Access Device (SSC-5) M = Mandatory
. P - Processor Device (SPC-2) O = Optional
. .R - C/DVD Device (MMC-6) V = Vendor specific
. . O - Optical Memory Block Device (SBC) Z = Obsolete -- with
. . M - Media Changer Device (SMC-3) [std] identifying
. . .A - Storage Array Device (SCC-2) last standard
. . . E - SCSI Enclosure Services device (SES-3)
. . . B - Simplified Direct-Access (Reduced Block) device (RBC)
. . . .K - Optical Card Reader/Writer device (OCRW)
. . . . V - Automation/Device Interface device (ADC-4)
. . . . F - Object-based Storage Device (OSD-2)
. . . . .
OP DZTPROMAEBKVF Description
08 GET MESSAGE(6)
25 GET WINDOW
28 GET MESSAGE(10)
34 GET DATA BUFFER STATUS
46 M GET CONFIGURATION
4A M GET EVENT STATUS NOTIFICATION
A8 GET MESSAGE(12)
AC O GET PERFORMANCE
top - bottom
D - Direct Access Block Device (SBC-4) Device Column key
.Z - Host managed zoned block device (ZBC) ---------------------
. T - Sequential Access Device (SSC-5) M = Mandatory
. P - Processor Device (SPC-2) O = Optional
. .R - C/DVD Device (MMC-6) V = Vendor specific
. . O - Optical Memory Block Device (SBC) Z = Obsolete -- with
. . M - Media Changer Device (SMC-3) [std] identifying
. . .A - Storage Array Device (SCC-2) last standard
. . . E - SCSI Enclosure Services device (SES-3)
. . . B - Simplified Direct-Access (Reduced Block) device (RBC)
. . . .K - Optical Card Reader/Writer device (OCRW)
. . . . V - Automation/Device Interface device (ADC-4)
. . . . F - Object-based Storage Device (OSD-2)
. . . . .
OP DZTPROMAEBKVF Description
07 O INITIALIZE ELEMENT STATUS
12 MMMMMMMMMMMMM INQUIRY
37 O INITIALIZE ELEMENT STATUS WITH RANGE
top - bottom
D - Direct Access Block Device (SBC-4) Device Column key
.Z - Host managed zoned block device (ZBC) ---------------------
. T - Sequential Access Device (SSC-5) M = Mandatory
. P - Processor Device (SPC-2) O = Optional
. .R - C/DVD Device (MMC-6) V = Vendor specific
. . O - Optical Memory Block Device (SBC) Z = Obsolete -- with
. . M - Media Changer Device (SMC-3) [std] identifying
. . .A - Storage Array Device (SCC-2) last standard
. . . E - SCSI Enclosure Services device (SES-3)
. . . B - Simplified Direct-Access (Reduced Block) device (RBC)
. . . .K - Optical Card Reader/Writer device (OCRW)
. . . . V - Automation/Device Interface device (ADC-4)
. . . . F - Object-based Storage Device (OSD-2)
. . . . .
OP DZTPROMAEBKVF Description
1B O M LOAD UNLOAD
2B M LOCATE(10)
36 Z O O LOCK UNLOCK CACHE(10)
4C OOOO OOOO OOO LOG SELECT
4D OMOO OOOO OMO LOG SENSE
92 Z O LOCK UNLOCK CACHE(16)
92 M LOCATE(16)
A6 O LOAD/UNLOAD C/DVD
top - bottom
D - Direct Access Block Device (SBC-4) Device Column key
.Z - Host managed zoned block device (ZBC) ---------------------
. T - Sequential Access Device (SSC-5) M = Mandatory
. P - Processor Device (SPC-2) O = Optional
. .R - C/DVD Device (MMC-6) V = Vendor specific
. . O - Optical Memory Block Device (SBC) Z = Obsolete -- with
. . M - Media Changer Device (SMC-3) [std] identifying
. . .A - Storage Array Device (SCC-2) last standard
. . . E - SCSI Enclosure Services device (SES-3)
. . . B - Simplified Direct-Access (Reduced Block) device (RBC)
. . . .K - Optical Card Reader/Writer device (OCRW)
. . . . V - Automation/Device Interface device (ADC-4)
. . . . F - Object-based Storage Device (OSD-2)
. . . . .
OP DZTPROMAEBKVF Description
15 O M OOOO OO MODE SELECT(6)
1A O M OOOO OO MODE SENSE(6)
38 O O MEDIUM SCAN
55 OMO MOOOOMOMO MODE SELECT(10)
5A OMO MOOOOMOMO MODE SENSE(10)
A3 OMO OOMOOOM MAINTENANCE IN
A4 OOO OOOOOOO MAINTENANCE OUT
A5 Z OM MOVE MEDIUM
A7 Z Z O MOVE MEDIUM ATTACHED
BD O MECHANISM STATUS
top - bottom
D - Direct Access Block Device (SBC-4) Device Column key
.Z - Host managed zoned block device (ZBC) ---------------------
. T - Sequential Access Device (SSC-5) M = Mandatory
. P - Processor Device (SPC-2) O = Optional
. .R - C/DVD Device (MMC-6) V = Vendor specific
. . O - Optical Memory Block Device (SBC) Z = Obsolete -- with
. . M - Media Changer Device (SMC-3) [std] identifying
. . .A - Storage Array Device (SCC-2) last standard
. . . E - SCSI Enclosure Services device (SES-3)
. . . B - Simplified Direct-Access (Reduced Block) device (RBC)
. . . .K - Optical Card Reader/Writer device (OCRW)
. . . . V - Automation/Device Interface device (ADC-4)
. . . . F - Object-based Storage Device (OSD-2)
. . . . .
OP DZTPROMAEBKVF Description
1B O OPEN/CLOSE IMPORT/EXPORT ELEMENT
31 OBJECT POSITION
8B O ORWRITE
top - bottom
D - Direct Access Block Device (SBC-4) Device Column key
.Z - Host managed zoned block device (ZBC) ---------------------
. T - Sequential Access Device (SSC-5) M = Mandatory
. P - Processor Device (SPC-2) O = Optional
. .R - C/DVD Device (MMC-6) V = Vendor specific
. . O - Optical Memory Block Device (SBC) Z = Obsolete -- with
. . M - Media Changer Device (SMC-3) [std] identifying
. . .A - Storage Array Device (SCC-2) last standard
. . . E - SCSI Enclosure Services device (SES-3)
. . . B - Simplified Direct-Access (Reduced Block) device (RBC)
. . . .K - Optical Card Reader/Writer device (OCRW)
. . . . V - Automation/Device Interface device (ADC-4)
. . . . F - Object-based Storage Device (OSD-2)
. . . . .
OP DZTPROMAEBKVF Description
0A PRINT
1E O O OOO O O PREVENT ALLOW MEDIUM REMOVAL
2B O POSITION TO ELEMENT
34 O O O PRE-FETCH(10)
45 O PLAY AUDIO(10)
47 O PLAY AUDIO MSF
4B O PAUSE/RESUME
5E OOMO OOOO M PERSISTENT RESERVE IN
5F OOMO OOOO M PERSISTENT RESERVE OUT
90 O O O PRE-FETCH(16)
A5 O PLAY AUDIO(12)
top - bottom
D - Direct Access Block Device (SBC-4) Device Column key
.Z - Host managed zoned block device (ZBC) ---------------------
. T - Sequential Access Device (SSC-5) M = Mandatory
. P - Processor Device (SPC-2) O = Optional
. .R - C/DVD Device (MMC-6) V = Vendor specific
. . O - Optical Memory Block Device (SBC) Z = Obsolete -- with
. . M - Media Changer Device (SMC-3) [std] identifying
. . .A - Storage Array Device (SCC-2) last standard
. . . E - SCSI Enclosure Services device (SES-3)
. . . B - Simplified Direct-Access (Reduced Block) device (RBC)
. . . .K - Optical Card Reader/Writer device (OCRW)
. . . . V - Automation/Device Interface device (ADC-4)
. . . . F - Object-based Storage Device (OSD-2)
. . . . .
OP DZTPROMAEBKVF Description
01 M REWIND
01 Z ZZZ REZERO UNIT
03 MMMMMMMMMOMMM REQUEST SENSE
05 V MVV V READ BLOCK LIMITS
07 O V OV REASSIGN BLOCKS
08 Z M OV READ(6)
08 O RECEIVE
0F V OVV V READ REVERSE(6)
14 V OVV RECOVER BUFFERED DATA
16 Z ZZ OOOZ O RESERVE(6)
16 Z RESERVE ELEMENT(6)
17 Z ZZ OOOZ O RELEASE(6)
17 Z RELEASE ELEMENT(6)
1C O OO OOOM OOO RECEIVE DIAGNOSTIC RESULTS
23 O READ FORMAT CAPACITIES
OP DZTPROMAEBKVF Description
25 M M M READ CAPACITY(10)
25 O READ CAPACITY
25 M READ CARD CAPACITY
28 M OM MM READ(10)
29 V VO READ GENERATION
2D O READ UPDATED BLOCK
34 M READ POSITION
37 O O READ DEFECT DATA(10)
3C OOOOOOOOO OOO READ BUFFER(10)
3E Z Z READ LONG(10)
42 O READ SUB-CHANNEL
43 O READ TOC/PMA/ATIP
44 M M REPORT DENSITY SUPPORT
44 READ HEADER
51 O READ DISC INFORMATION
OP DZTPROMAEBKVF Description
52 O READ TRACK INFORMATION
53 O RESERVE TRACK
56 Z ZZ OOOZ RESERVE(10)
56 Z RESERVE ELEMENT(10)
57 Z ZZ OOOZ RELEASE(10)
57 Z RELEASE ELEMENT(10)
58 O REPAIR TRACK
5C O READ BUFFER CAPACITY
81 Z REBUILD(16)
81 O READ REVERSE(16)
82 Z REGENERATE(16)
88 MMO O O READ(16)
8C O O OO O M READ ATTRIBUTE
9B OOO OOO O READ BUFFER(16)
A0 MMMO OMMM OMO REPORT LUNS
OP DZTPROMAEBKVF Description
A4 O REPORT KEY
A8 O OO READ(12)
AD O READ DVD STRUCTURE
B4 Z Z ZO READ ELEMENT STATUS ATTACHED
B5 O REQUEST VOLUME ELEMENT ADDRESS
B7 OO O READ DEFECT DATA(12)
B8 Z ZOM READ ELEMENT STATUS
B9 O READ CD MSF
BA O OOMO REDUNDANCY GROUP (IN)
BB O OOOO REDUNDANCY GROUP (OUT)
BE O READ CD
top - bottom
D - Direct Access Block Device (SBC-4) Device Column key
.Z - Host managed zoned block device (ZBC) ---------------------
. T - Sequential Access Device (SSC-5) M = Mandatory
. P - Processor Device (SPC-2) O = Optional
. .R - C/DVD Device (MMC-6) V = Vendor specific
. . O - Optical Memory Block Device (SBC) Z = Obsolete -- with
. . M - Media Changer Device (SMC-3) [std] identifying
. . .A - Storage Array Device (SCC-2) last standard
. . . E - SCSI Enclosure Services device (SES-3)
. . . B - Simplified Direct-Access (Reduced Block) device (RBC)
. . . .K - Optical Card Reader/Writer device (OCRW)
. . . . V - Automation/Device Interface device (ADC-4)
. . . . F - Object-based Storage Device (OSD-2)
. . . . .
OP DZTPROMAEBKVF Description
0A M SEND(6)
0A SEND MESSAGE(6)
0B Z OZV SEEK(6)
0B O SET CAPACITY
0B SLEW AND PRINT
10 SYNCHRONIZE BUFFER
11 V MVV SPACE(6)
1B OM OO O MO O START STOP UNIT
1B SCAN
1B STOP PRINT
1D MOMM MMOM MMM SEND DIAGNOSTIC
24 V V SET WINDOW
2A SEND(10)
2A SEND MESSAGE(10)
2B Z OO O SEEK(10)
OP DZTPROMAEBKVF Description
30 Z ZZ SEARCH DATA HIGH(10)
31 Z ZZ SEARCH DATA EQUAL(10)
32 Z ZZ SEARCH DATA LOW(10)
33 Z ZO SET LIMITS(10)
35 O OO MO SYNCHRONIZE CACHE(10)
48 OO O SANITIZE
4E O STOP PLAY/SCAN
54 O SEND OPC INFORMATION
5D O SEND CUE SHEET
91 OM O O SYNCHRONIZE CACHE(16)
91 O SPACE(16)
9D SERVICE ACTION BIDIRECTIONAL
9E OM SERVICE ACTION IN(16)
9F M SERVICE ACTION OUT(16)
A2 OOO O O SECURITY PROTOCOL IN
OP DZTPROMAEBKVF Description
A3 O SEND KEY
A7 O SET READ AHEAD
A9 O SERVICE ACTION OUT(12)
AA SEND MESSAGE(12)
AB O O SERVICE ACTION IN(12)
B0 ZZ SEARCH DATA HIGH(12)
B1 ZZ SEARCH DATA EQUAL(12)
B2 ZZ SEARCH DATA LOW(12)
B3 Z ZO SET LIMITS(12)
B5 OOO O O SECURITY PROTOCOL OUT
B6 O SEND VOLUME TAG
B6 O SET STREAMING
BA O SCAN
BB O SET CD SPEED
BC O OOMO SPARE (IN)
OP DZTPROMAEBKVF Description
BD O OOOO SPARE (OUT)
BF O SEND DVD STRUCTURE
top - bottom
D - Direct Access Block Device (SBC-4) Device Column key
.Z - Host managed zoned block device (ZBC) ---------------------
. T - Sequential Access Device (SSC-5) M = Mandatory
. P - Processor Device (SPC-2) O = Optional
. .R - C/DVD Device (MMC-6) V = Vendor specific
. . O - Optical Memory Block Device (SBC) Z = Obsolete -- with
. . M - Media Changer Device (SMC-3) [std] identifying
. . .A - Storage Array Device (SCC-2) last standard
. . . E - SCSI Enclosure Services device (SES-3)
. . . B - Simplified Direct-Access (Reduced Block) device (RBC)
. . . .K - Optical Card Reader/Writer device (OCRW)
. . . . V - Automation/Device Interface device (ADC-4)
. . . . F - Object-based Storage Device (OSD-2)
. . . . .
OP DZTPROMAEBKVF Description
00 MMMMMMMMMMMMM TEST UNIT READY
83 O OO O OO Third-party Copy OUT
84 O OO O OO Third-party Copy IN
top - bottom
D - Direct Access Block Device (SBC-4) Device Column key
.Z - Host managed zoned block device (ZBC) ---------------------
. T - Sequential Access Device (SSC-5) M = Mandatory
. P - Processor Device (SPC-2) O = Optional
. .R - C/DVD Device (MMC-6) V = Vendor specific
. . O - Optical Memory Block Device (SBC) Z = Obsolete -- with
. . M - Media Changer Device (SMC-3) [std] identifying
. . .A - Storage Array Device (SCC-2) last standard
. . . E - SCSI Enclosure Services device (SES-3)
. . . B - Simplified Direct-Access (Reduced Block) device (RBC)
. . . .K - Optical Card Reader/Writer device (OCRW)
. . . . V - Automation/Device Interface device (ADC-4)
. . . . F - Object-based Storage Device (OSD-2)
. . . . .
OP DZTPROMAEBKVF Description
3D O UPDATE BLOCK
42 O UNMAP
top - bottom
D - Direct Access Block Device (SBC-4) Device Column key
.Z - Host managed zoned block device (ZBC) ---------------------
. T - Sequential Access Device (SSC-5) M = Mandatory
. P - Processor Device (SPC-2) O = Optional
. .R - C/DVD Device (MMC-6) V = Vendor specific
. . O - Optical Memory Block Device (SBC) Z = Obsolete -- with
. . M - Media Changer Device (SMC-3) [std] identifying
. . .A - Storage Array Device (SCC-2) last standard
. . . E - SCSI Enclosure Services device (SES-3)
. . . B - Simplified Direct-Access (Reduced Block) device (RBC)
. . . .K - Optical Card Reader/Writer device (OCRW)
. . . . V - Automation/Device Interface device (ADC-4)
. . . . F - Object-based Storage Device (OSD-2)
. . . . .
OP DZTPROMAEBKVF Description
13 O VERIFY(6)
2F O OO VERIFY(10)
8F OOO O O VERIFY(16)
AF O O VERIFY(12)
BE O OOMO VOLUME SET (IN)
BF O OOOO VOLUME SET (OUT)
top - bottom
D - Direct Access Block Device (SBC-4) Device Column key
.Z - Host managed zoned block device (ZBC) ---------------------
. T - Sequential Access Device (SSC-5) M = Mandatory
. P - Processor Device (SPC-2) O = Optional
. .R - C/DVD Device (MMC-6) V = Vendor specific
. . O - Optical Memory Block Device (SBC) Z = Obsolete -- with
. . M - Media Changer Device (SMC-3) [std] identifying
. . .A - Storage Array Device (SCC-2) last standard
. . . E - SCSI Enclosure Services device (SES-3)
. . . B - Simplified Direct-Access (Reduced Block) device (RBC)
. . . .K - Optical Card Reader/Writer device (OCRW)
. . . . V - Automation/Device Interface device (ADC-4)
. . . . F - Object-based Storage Device (OSD-2)
. . . . .
OP DZTPROMAEBKVF Description
0A Z O OV WRITE(6)
10 V MVV WRITE FILEMARKS(6)
2A O OM MO WRITE(10)
2E O OO MO WRITE AND VERIFY(10)
3B OOOOOOOOOMOOO WRITE BUFFER
3F O O WRITE LONG(10)
41 O WRITE SAME(10)
80 M WRITE FILEMARKS(16)
8A OMO O O WRITE(16)
8D O O OO O O WRITE ATTRIBUTE
8E O O O WRITE AND VERIFY(16)
93 OM WRITE SAME(16)
9A OO WRITE STREAM(16)
9C O WRITE ATOMIC(16)
AA O OO WRITE(12)
OP DZTPROMAEBKVF Description
AE O O WRITE AND VERIFY(12)
top - bottom
D - Direct Access Block Device (SBC-4) Device Column key
.Z - Host managed zoned block device (ZBC) ---------------------
. T - Sequential Access Device (SSC-5) M = Mandatory
. P - Processor Device (SPC-2) O = Optional
. .R - C/DVD Device (MMC-6) V = Vendor specific
. . O - Optical Memory Block Device (SBC) Z = Obsolete -- with
. . M - Media Changer Device (SMC-3) [std] identifying
. . .A - Storage Array Device (SCC-2) last standard
. . . E - SCSI Enclosure Services device (SES-3)
. . . B - Simplified Direct-Access (Reduced Block) device (RBC)
. . . .K - Optical Card Reader/Writer device (OCRW)
. . . . V - Automation/Device Interface device (ADC-4)
. . . . F - Object-based Storage Device (OSD-2)
. . . . .
OP DZTPROMAEBKVF Description
50 Z XDWRITE(10)
51 O XPWRITE(10)
52 Z XDREAD(10)
53 O XDWRITEREAD(10)
80 Z XDWRITE EXTENDED(16)
top - bottom
D - Direct Access Block Device (SBC-4) Device Column key
.Z - Host managed zoned block device (ZBC) ---------------------
. T - Sequential Access Device (SSC-5) M = Mandatory
. P - Processor Device (SPC-2) O = Optional
. .R - C/DVD Device (MMC-6) V = Vendor specific
. . O - Optical Memory Block Device (SBC) Z = Obsolete -- with
. . M - Media Changer Device (SMC-3) [std] identifying
. . .A - Storage Array Device (SCC-2) last standard
. . . E - SCSI Enclosure Services device (SES-3)
. . . B - Simplified Direct-Access (Reduced Block) device (RBC)
. . . .K - Optical Card Reader/Writer device (OCRW)
. . . . V - Automation/Device Interface device (ADC-4)
. . . . F - Object-based Storage Device (OSD-2)
. . . . .
OP DZTPROMAEBKVF Description
94 OM ZBC OUT
95 OM ZBC IN
top - bottom
D - Direct Access Block Device (SBC-4) Device Column key
.Z - Host managed zoned block device (ZBC) ---------------------
. T - Sequential Access Device (SSC-5) M = Mandatory
. P - Processor Device (SPC-2) O = Optional
. .R - C/DVD Device (MMC-6) V = Vendor specific
. . O - Optical Memory Block Device (SBC) Z = Obsolete -- with
. . M - Media Changer Device (SMC-3) [std] identifying
. . .A - Storage Array Device (SCC-2) last standard
. . . E - SCSI Enclosure Services device (SES-3)
. . . B - Simplified Direct-Access (Reduced Block) device (RBC)
. . . .K - Optical Card Reader/Writer device (OCRW)
. . . . V - Automation/Device Interface device (ADC-4)
. . . . F - Object-based Storage Device (OSD-2)
. . . . .
OP DZTPROMAEBKVF Description
7E O O O OOOO O extended CDB
top - bottom
D - Direct Access Block Device (SBC-4) Device Column key
.Z - Host managed zoned block device (ZBC) ---------------------
. T - Sequential Access Device (SSC-5) M = Mandatory
. P - Processor Device (SPC-2) O = Optional
. .R - C/DVD Device (MMC-6) V = Vendor specific
. . O - Optical Memory Block Device (SBC) Z = Obsolete -- with
. . M - Media Changer Device (SMC-3) [std] identifying
. . .A - Storage Array Device (SCC-2) last standard
. . . E - SCSI Enclosure Services device (SES-3)
. . . B - Simplified Direct-Access (Reduced Block) device (RBC)
. . . .K - Optical Card Reader/Writer device (OCRW)
. . . . V - Automation/Device Interface device (ADC-4)
. . . . F - Object-based Storage Device (OSD-2)
. . . . .
OP DZTPROMAEBKVF Description
7F O M variable length CDB (more than 16 bytes)
top - bottom
Return to the SCSI Common Codes & Values page